PowerSonic rechargeable sealed lead acid battery. 6V 7.0 AH with 0.187″ quick disconnect terminals.
Product Features:
Specifications:
Nominal Voltage: 6 volts (3 cells in series)
Nominal Capacity:
20 hour rate (350mA to 5.25 volts) ………….7.00 A.H.
10 hour rate (630mA to 5.25 volts) ………….6.30 A.H.
5 hour rate (1.19A to 5.10 volts)………….5.95 A.H.
1 hour rate (4.30A to 4.50 volts) ………….4.30 A.H.
Approximate Weight: 2.80 pounds (1.27 kg)
Energy Density (20 hour rate): 1.42 Watt-hours/cubic inch (87.0 Watt-hours/l)
Specific Energy (20 hour rate) : 14.3 Watt-hours/pound (31.6 Watt-hours/kg)
Internal Resistance (Fully Charged Battery): 15 milliohms (approximately)
Maximum Discharge Current ( 7 Min.): 21 amperes
Maximum Short-Duration Discharge Current ( 10 Sec.): 70 amperes
Terminal configurations: F1: 0.187″ quick disconnect terminals
Shelf Life – % of nominal capacity at 68 F (20 C):
1 Month: 97%
3 Months: 91%
6 Months: 83%
Operating Temperature Range:
Charge: -4F (-20C) to 122F (50C)
Discharge: -4F (-20C) to 140F (60C)
Case: ABS Plastic
Charging Characteristics:
Cycle Applications: Limit initial current to 2.10A. Charge until battery voltage (under charge) reaches 7.20 to 7.35 volts at 68F (20C). Hold at 7.20 to 7.35 volts until current drops to approximately 70mA. Battery is fully charged under these conditions, and charger should either be disconnected or switched to “float” voltage.
“Float” or “Stand-By” Service: Hold battery across constant voltage source of 6.75 to 6.90 volts continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition.
NOTE: Due to the self-discharge characteristics of this type of battery, it is imperative that they be charged after 6-9 months of storage, otherwise permanent loss of capacity might occur as a result of sulfation.